You have no items in your shopping basket.
Fluke 1587 Insulation Tester Meg Ohm Meter/Tester
Be the first to review this product
Quick Overview
Two powerful tools in one.
The Fluke 1587 Insulation Multimeter combines a digital insulation tester with a full-featured, true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
Like other tools that you have come to expect from Fluke, the 1588 is rugged, reliable, and easy to use.
Whether you work on motors, generators, cables, or switch-gear, the Fluke 1587 Insulation Multimeter is ideally suited to help you with your tasks.
- Large display with backlight
- Insulation test 0.01 MW to 2 GW
- Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V for many applications
- Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
- Auto-discharge of capacitive voltage for added user protection
- AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance (W), Continuity
- Filter for motor drive measurements
- Capacitance, diode test, temperature, Min/Max, frequency (Hz)
- Auto power off to save battery power
- CAT III 1000 V, CAT IV 600 V measurement category
- Accepts optional Fluke TPAK™ magnetic hanging system to free your hands for other work
- Rugged, utility hard case allows you to bring everything you need for the job
- 3-year warranty
Included
- Remote probe
- Test leads
- Alligator clips
- K-type thermocouple
- Hard case
- User documentation
General Specifications
- Maximum voltage applied to any terminal
1000 V ac rms or dc - Storage temperature
-40 °C to 60 °C (-40 °F to 140 °F) - Operating temperature
-20 °C to 55 °C (-4 °F to 131 °F) - Temperature coefficient
0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F) - Relative humidity, non-condensing: < °C
0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F)
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F)
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) - Vibration
Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument - Shock
1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) - Electromagnetic compatibility
In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ± 5 °C (9 °F). (EN 61326-1:1997) - Safety
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V - Certifications
CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard EN 61010 Part 1-1002 - Batteries
Four AA batteries (NEDA 15A or IEC LR6) - Battery life
Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MW with a duty cycle of 5 seconds on and 25 seconds off - Size
5.0 cm H x 10.0 cm W x 20.3 cm L
1.97 in H x 3.94 in W x 8.00 in L - Weight
550 g (1.2 lb) - IP rating
IP40 - Altitude (operating)
2000 m CAT III 1000 V, CAT IV 600 V
3000 m CAT II 1000 V, CAT III 600 V - Storage
12,000 m - Over-range capability
110 % of range except for capacitance which is 1 % - Compliance to EN 61557
IEC61557-1, IEC61557-2
Product Tags/Keywords
Add Your Tags/Keywords:
Technical Specification
Accuracy
| Range | Resolution | 50 Hz to 60 Hz | 60 Hz to 5000 Hz |
|---|---|---|---|
| 600.0 mV | 0.1 mV | + (1 % + 3) | + (2 % + 3) |
| 6.000 V | 0.001 V | + (1 % + 3) | + (2 % + 3) |
| 60.00 V | 0.01 V | + (1 % + 3) | + (2 % + 3) |
| 600.0 V | 0.1 V | + (1 % + 3) | + (2 % + 3)1 |
| 1000 V | 1 V | + (2 % + 3) | + (2 % + 3)1 |
11 kHz bandwidth
Lowpass Filter Voltage
| Range | Resolution | 50 Hz to 60 Hz | 60 Hz to 400 Hz |
|---|---|---|---|
| 600.0 mV | 0.1 mV | + (1 % + 3) | + (2 % + 3) |
| 6.000 V | 0.001 V | + (1 % + 3) | + (2 % + 3) |
| 60.00 V | 0.01 V | + (1 % + 3) | + (2 % + 3) |
| 600.0 V | 0.1 V | + (1 % + 3) | + (2 % + 3) |
| 1000 V | 1 V | + (2 % + 3) | + (2 % + 3) |
- AC conversion
Inputs are ac-coupled and calibrated to the rms value of sine wave input. Conversions are true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor can be up to 3 at full scale up to 500 V, decreasing linearly to crest factor < = 1.5 at 1000 V. For non-sinusoidal waveforms add ± (2 % reading + 2 % FS) typical, for a crest factor up to 3. - Input impedance
10 MW (nominal), < 100 pF, ac-coupled - Common mode rejection ratio (1 kW unbalanced)
> 60 dB at dc, 50 or 60 Hz - Overload protection
1000 V rms or dc, 107 V Hz Max
DC Voltage Measurement
| Range | Resolution | Accuracy 15871 |
|---|---|---|
| 6.000 V dc | 0.001 V | 0.09 % + 2 |
| 60.00 V dc | 0.01 V | 0.09 % + 2 |
| 600.0 V dc | 0.1 V | 0.09 % + 2 |
| 1000 V dc | 1 V | 0.09 % + 2 |
1Accuracies apply to ± 100 % of range
- Input impedance
10 MW (nominal), < 100 pF - Normal mode rejection ratio
> 60 dB @ 50 Hz or 60 Hz - Common rode rejection ratio
> 120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance) - Overload protection
1000 V rms or dc
DC Millivolts Measurement
| Range | Resolution | Accuracy 1587 |
|---|---|---|
| 600.0 mV dc | 0.1 mV | 0.1 % + 1 |
DC and ac current measurement
| Range | Resolution | Accuracy 1587 ± (% of Rdg+Digits) | Accuracy 1577 ± (% of Rdg+Digits) | Burden Voltage (Typical) | |
|---|---|---|---|---|---|
| AC 45 to 1000 Hz | 400 mA | 0.1 mA | ± (1.5 % + 2)1 | ± (2 % + 2)1 | 2 mV/mA |
| 60 mA | 0.01 mA | ± (1.5 % + 2)1 | ± (2 % + 2)1 | ||
| DC | 400 mA | 0.1 mA | ± (0.2 % + 2) | ± (1.0 % + 2) | 2 mV/mA |
| 60 mA | 0.01 mA | ± (0.2 % + 2) | ± (1.0 % + 2) | ||
11 kHz bandwidth
- Overload
600 mA for 2 minutes maximum - Overload protection
440 mA, 1000 V, FAST fuse - AC conversion
Inputs are ac-coupled and calibrated to the rms value of sine wave input. Conversions are true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor can be up to 3 at full scale up to 300 mA, decreasing linearly to crest factor < = 1.5 at 600 mA. For non-sinusoidal waveforms add + (2 % reading + 2 % FS) typical, for a crest factor up to 3.
Ohms measurement
| Range | Resolution | Accuracy 15871 ± (% of Rdg+Digits) | Accuracy 15871± (% of Rdg+Digits) |
|---|---|---|---|
| 600.0 O | 0.1 O | 0.9 % + 2 | 1.2 % + 2 |
| 6.000 kΩ | 0.001 kΩ | ||
| 60.00 kΩ | 0.01 kΩ | ||
| 600.0 kΩ | 0.1 kΩ | ||
| 6.000 MΩ | 0.001 MΩ | ||
| 50.0 MΩ | 0.01 MΩ | 1.5 % + 3 | 2.0 % + 3 |
1Accuracies apply from 0 to 100 % of range
- Overload protection
1000 V rms or dc - Open circuit test voltage
< 8.0 V dc - Short circuit current
< 1.1 mA
Diode test
- Diode test indication
Display voltage drop: 0.6 V at 1.0 mA nominal test current
Accuracy: + (2 % + 1)
Continuity test
- Continuity indication
Continuous audible tone for test resistance below 25 W and off above 100 W. - Maximum reading
1000 W - Open circuit voltage
< 8.0 V - Short circuit current
1.0 mA typical - Overload protection
1000 V rms - Response time
> 1 m sec
Frequency measurement
| Range | Resolution | Acuracy ± (% of Rdg+Digits) |
|---|---|---|
| 99.99 Hz | 0.01 Hz | ± (0.1 % + 1) |
| 999.9 Hz | 0.1 Hz | ± (0.1 % + 1) |
| 9.999 kHz | 0.001 kHz | ± (0.1 % + 1) |
| 99.99 kHz | 0.01 kHz | ± (0.1 % + 1) |
Frequency counter sensitivity
| Input Range | V ac Sensitivity (RMS Sinewave)1 | DC Trigger Levels to 20 kHz2 | |
|---|---|---|---|
| 5 Hz to 20 kHz | 20 kHz to 100 kHz | ||
| 600.0 mV ac | 150.0 mV | 150.0 mV | N/A |
| 6.0 V | 0.3 V | 0.7 V | -400.0 mV and 2.5 V |
| 60.0 V | 3.0 V | 10.0 V | 1.5 V and 4.0 V |
| 600.0 V | 35.0 V | 100.0 V | 15.0 V and 40.0 V |
| 1000.0 V | 200.0 V | 700.0 V | 15.0 V and 40.0 V |
1Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy.2Usable to 100 kHz with full scale input.
Capacitance
| Range | Resolution | ± (% of Rdg+Digits) |
|---|---|---|
| 1000 nF | 1 nF | ± (1.2 % + 2) |
| 10.00 µF | 0.01 µF | |
| 100.0 µF | 0.1 µF | |
| 9999 µF | 1 µF | ± (1.2 % +/- 90 counts) |
Temperature measurement
| Range | Resolution | Accuracy1 |
|---|---|---|
| -40 °C to 537 °C | 0.1 °C | 1 % + 10 counts |
| -40 °F to 998 °F | 0.1 °F | 1 % + 18 counts |
1Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
Insulation specifications
- Measurement range
0.01 MW to 2 GW - Test voltages
50, 100, 250, 500, 1000 V - Test voltage accuracy
+ 20 %, - 0 % - Short-circuit test current
1 mA nominal - Auto discharge
Discharge time < 0.5 second for C = 1 μF or less - Live circuit detection
Inhibit test if terminal voltage > 30 V prior to initialization of test - Maximum capacitive load
Operable with up to 1 μF load
| 1587 | |
|---|---|
| Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V | • |
| Insulation test voltages 500 V, 1000 V | |
| Insulation test: 0.01 MΩ to 2.0 GO | • |
| Insulation test: 0.1 MΩ to 600 MΩ | |
| Auto-discharge of capacitive voltage | • |
| Insulation test smootding reading | • |
| Frequency | • |
| Capacitance | • |
| Diode test | • |
| Temperature | • |
| Min/Max | • |
| Low pass filter (for work on VSDs) | • |
| AC/DC Voltage | • |
| DC Millivolts | • |
| AC/DC milliAmps | • |
| Resistance (0.1 O to 50 MΩ) | • |
| Continuity | • |
| tdree-year warranty | • |
| Remote probe, test leads, alligator clips | • |
| K-type tdermocouple | • |
| Rugged, utility hard case | • |
| Auto power off | • |