Metrel Eurotest 61557

Be the first to review this product

Our Price:

RRP: £ 995.00
Our Price: £ 796.00
Add Items to Cart OR

Quick Overview

Advanced, multifunctional digital measuring instrument for low voltage electrical installation safety testing in accordance with IEC / EN 61557.

Best selling installation tester in Europe!

Measuring Functions

BetaPAT is suitable for periodic testing, troubleshooting or as a tool for electrical safety testing in workshops.

  • DC insulation resistance measurement,
  • PE voltage drop / earth bond continuity test,
  • leakage current measurement and functional test.
  • Other features

  • 120 Pre-programmed Autotest sequences are stored in the instrument's memory and they cover most of the test procedures required by PAT standards. Autotest sequences give information on allowed standard-set  limits for all test parameters and essentially accelerate measuring procedure.
  • Possibility to create and store Custom Autotests sequences.
    Multifunction, alphanumeric keyboard allows specific data entries (appliance description, location, etc.).
  • Appliance identification and access to the test sequence via Barcode reader or RFID tags.
  • BetaPAT  MI2141 is suitable for applications where AC dielectric test is not required (e.g. periodic testing).
  • Optional: 110 V version.
  • Software

    PC software Pat Link with RS 232 cable

    Technical data

    Dimensions (w x h x l): 345 x 160 x 335 mm

    Mass (without accessories): 9 kg

    ►   Insulation Resistance
    Display range 0 – 1000MOhms (Un=250 V) 0 – 200 MOhms (Un<250 V)
    Resolution 0.001 0.01 0.1 1 MOhms
    Accuracy ±(2 % + 2 Digits)…(0 – 200 MOhms)
    Test voltage 50 100 250 500 1000 V
    Generator current capability >1 mA

    ►   Continuity of Protection Conductors (single measurement)
    Display range 0.00 – 19.99 20.0 – 199.9 200 - 2000 Ohms
    Accuracy ±(2 % + 2 Digits)….(0 – 20 O)
    Open-terminal test voltage 4 – 7 Vd.c.
    Test current >200 mA
    Compensation of test leads yes
    Automatic polarity exchange yes

    ►   Continuity (continuous measurement)
    Display range 0.0 – 199.9 Ohms 200 – 2000 Ohms
    Accuracy ±(3 % + 3 Digits)
    Short-circuit test current <7 mA
    Open-terminal voltage 4 – 7 Vd.c.

    ►   RCD Protection Devices – general data
    Nom. test current 10; 30; 100; 300; 500; 1000 mA (0 or 180 °C)
    RCD type AC, standard or selective

    ►   RCD – Contact Voltage
    Display range 0.00 – 9.99 10.0 – 100 V
    Resolution 0.01 0.1 V
    Basic accuracy (-0 / +10)% ± 0.2 V (-0 / +10) %
    Test current <0.5 I?N

    ►   RCD – Earth/Loop Resistance
    Measurement principle with or without probe
    Display range 0 – 10 kO

    ►   RCD – Trip out Time
    Display range (general type) 0 – 300 ms (0.5 I?N, I?N)
    0 – 150 ms (2 I?N) 0 – 40 ms (5 I?N)
    Display range (selective type) 0 – 500 ms (0.5 I?N, I?N)
    0 – 200ms (2 I?N) 0 – 150 ms (5 I?N)
    Accuracy ±3 ms

    ►   RCD – Tripping Current
    Display range I? (0.2 – 1.1) I?N
    Display range t?/I? 0 – 300 ms
    Display range Uci (Uc/I?) 0 – 100 V

    ►   Fault Loop Impedance / Resistance and Ipsc
    Display range Z, R, X 0.00 – 19.99 20.0 – 199.9 200 – 2000 Ohms
    Accuracy Z, R, X …Eurotest ±(2 % + 3 Digits)
    Accuracy R…Instaltest ±(5 % + 5 Digits)
    Display range Ipsc 0.06 A – 24.4 kA
    Nominal voltage 100 – 264 V 45 – 65 Hz

    ►   Line Impedance / Resistance and Ipsc
    Display range Z, R, X 0.00 – 19.99 20.0 – 199.9 200 – 2000 Ohms
    Accuracy Z, R, X …Eurotest ±(2 % + 3 Digits)
    Accuracy R…Instaltest ±(5 % + 5 Digits)
    Display range Ipsc 0.06 A – 42.4 kA
    Nominal voltage 100 – 440 V 45 – 65 Hz

    ►   N-PE Loop / Earth Resistance and Ipsc
    Test method internal generator (Earth resistance)
    Display range R l-pe 0.00 – 19.99 20.0 – 199.9 200 – 2000 Ω
    Accuracy R l-pe ±(2 % + 3 Digits)
    Display range Ipsc 0.06 A – 24.4 kA

    ►   Phase rotation
    Display of result 1.2.3 or 2.1.3

    ►   Voltage              Frequency
    Display range 0 – 440V   45.0 – 65.0 Hz
    Accuracy ±(2 % + 2 D) ± 0.2 Hz
    Nominal frequency range 45 – 65 Hz

    ►   Current (True RMS)
    Measurement principle current clamp
    Display range 0 – 200 Amps
    Resolution 0.1 1 mA 0.01 0.1 1A
    Basic accuracy ±(5 %)…(0.1 – 100 Amps)
    Nominal frequency 50/60 Hz

    ►   Peak Current
    Display range 5 – 280 Amps
    Basic accuracy ±(5 %)

    ►   Varistor Overvoltage Protection. Devices – Breakdown Voltage
    Measurement principle d.c. voltage ramp (500 V/s)
    Display range 50 – 1000 V
    Accuracy ±(5 % + 10 V)

    ►   Power (one-phase)
    Display range 0 – 88 k W/VA/Var
    Resolution 0.1 1 0.01 k 0.1 k W/VA/Var
    Accuracy ±(7 % + 1 D)
    Nominal voltage, frequency 10 – 440 V, 50/60 Hz
    Display range cosϕ 0 – 1

    ►   Energy
    Calculation W = Σ P × Δt
    Display range 0 – 2000 kWh
    Accuracy ±(7 % + 1 Digits)

    ►   GENERAL CHARACTERISTICS:
    Power supply 6 V (4 × 1.5 V IEC LR14)
    Dimensions (w × h × d) 265 × 110 × 185 mm
    Weight: 2,1 kg.

    Product Tags/Keywords

    Add Your Tags/Keywords:
    Use spaces to separate tags. Use single quotes (') for phrases.

    Technical Specification

    Sorry there are no further technical specifications available for this product. Please call us for more information.

     

    My Basket

    You have no items in your shopping basket.

    Click for details of our price promise

    Laser Distance Meters

    PAT Training

    Newsletter