The Fluke 1507 Insulation Testers is compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting, commissioning, and preventative maintenance applications. Additional features, like the remote probe on these tools save both time and money when performing tests.

Features and benefits:

  • Insulation test range: 1507: 0.01 MW to 10 GW
  • Insulation test voltages: 1507: 50 V, 100 V, 250 V, 500 V, 1000 V (1507 only)
  • Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio
  • Make repetitive tests simple and easy with the 1507’s Compare (Pass/Fail) function (1507 only)
  • Repetitive or hard-to-reach testing is easy with the remote test probe
  • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
  • Auto-discharge of capacitive voltage for added user protection
  • AC/DC voltage: 0.1 V to 600 V
  • 200 mA Continuity
  • Resistance: 0.01 W to 20.00 KW
  • Save battery power with auto power off
  • Read measurements easily with large, backlit display
  • CAT IV 600 V overvoltage category rating for added user protection
  • Remote probe, test leads, probes and alligator clips included with each tester
  • Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
  • Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
  • One-year warranty

Included accessories

  • TL224 Test Leads,
  • TP74 Test Probes
  • Clips PN 1958654 (red) and PN 1958646 (black)
  • Holster and remote probe

General Specifications

  1. Maximum voltage applied to any terminal
    600 V ac rms or dc
  2. Storage temperature
    -40 °C to 60 °C
    (-40 °F to 140 °F)
  3. Operating temperature
    -20 °C to 55 °C
    (-4 °F to 131 °F)
  4. Temperature coefficient
    0.05 x (specified accuracy)
    per °C for temperatures < 18 °C or > 28 °C
    (< 64 °F or > 82 °F)
  5. Relative humidity noncondensing
    0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F)
    0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F)
    0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)
  6. Vibration
    Random, 2 g, 5-500 Hz per
    MIL-PRF-28800F, Class 2 instrument
  7. Shock
    1 meter drop per IEC 61010-1 2nd Edition
    (1 meter drop test, six sides, oak floor)
  8. Electromagnetic compatibility: In an RF field of
    3 V/M, accuracy = specified accuracy
    (EN 61326-1:1997)
  9. Safety
    Complies with ANSI/ISA 82.02.01 (61010-1)
    2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN
    61010-1 2nd Edition for measurement category IV
    600 V (CAT IV)
  10. Certifications
    CSA per standard CSA/CAN C22.2
    No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
  11. Batteries
    Four AA batteries (NEDA 15A or IEC LR6)
  12. Battery life Insulation test use
    Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MW with a duty cycle of 5 seconds on and 25 seconds off.
  13. Battery Life Resistance measurements
    Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 W with a duty cycle of 5 seconds on and 25 seconds off.
  14. Size
    5.0 cm H x 10.0 cm W x 20.3 cm L
    1.97 in H x 3.94 in W x 8.00 in L
  15. Weight
    550 g (1.2 lb)
  16. IP rating
    IP40
  17. Altitude Operating
    2000 m CAT IV 600 V,
    3000 m CAT III 600 V
  18. Non-operating (storage)
    12,000 m
  19. Over-range capability
    110 % of range

Technical Specification

AC/DC voltage measurement

Accuracy

Range Resolution 50 Hz to 400 Hz ± (% of Rdg + Digits)
600.0 V 0.1 V ± (2 % + 3)
  1. Input impedance
    3 MW (nominal), < 100 pF
  2. Common mode rejection ratio (1 kW unbalanced)
    > 60 dB at dc, 50 or 60 Hz
  3. Overload protection
    600 V rms or dc

Earth bond resistance measurement

Range Resolution Accuracy1 + (% of Rdg + Digits)
20.00 O 0.01 O ± (1.5 % + 3)
200.0 O 0.1 O
2000 O 1 O
20.00 kΩ 0.01 kΩ

1Accuracies apply from 0 to 100 % of range.

  1. Overload protection
    2 V rms or dc
  2. Open circuit test voltage
    > 4.0 V, < 8 V
  3. Short circuit current
    > 200.0 mA

Insulation specifications

  1. Measurement range
    0.01 MW to 2000 MW
  2. Test voltages
    50 V, 100 V, 250 V, 500 V, 1000 V
  3. Test voltage accuracy
    + 20 %, - 0 %
  4. Short-circuit test current
    1 mA nominal
  5. Auto discharge
    Discharge time < 0.5 second for C = 1 μF or less
  6. Live circuit detection
    Inhibit test if terminal voltage > 30 V prior to initialization of test
  7. Maximum capacitive load
    Operable with up to 1 μF load

Accuracy

Output Voltage Display Range Resolution Test Current Accuracy ± (% of Rdg + Digits)
50 V 0.01 MΩ to 20.00 MΩ 0.01 MΩ 1 mA @ 50 kΩ ± (3 % + 5)
(0 % to + 20 %) 20.0 MΩ to 50.0 MΩ 0.1 MΩ
100 V 0.01 MΩ to 20.00 MΩ 0.01 MΩ 1 mA @ 100 kΩ ± (3 % + 5)
(0 % to + 20 %) 20.0 MΩ to 100.0 MΩ 0.1 MΩ
250 V 0.01 MΩ to 20.00 MΩ 0.01 MΩ 1 mA @ 250 kΩ ± (1.5 % + 5)
(0 % to + 20 %) 20.0 MΩ to 200.0 MΩ 0.1 MΩ
500 V (0 % to + 20 %) 0.01 MΩ to 20.00 MΩ 0.01 MΩ 1 mA @ 500 kΩ ± (1.5 % + 5)
20.0 MΩ to 200.0 MΩ 0.1 MΩ
200 MΩ to 500 MΩ 1 MΩ
1000 V (0 % to + 20 %) 0.1 MΩ to 200.0 MΩ 0.1 MΩ 1 mA @ 1 MΩ ± (1.5 % + 5)
200 MΩ to 2000 MΩ 1 MΩ
2.0 GO to 10.0 GO 0.1 GO ± (10 % + 3)

EN61557 Specifications

The following tables are a requirement for European labeling.

Measurement Intrinsic Uncertainty Operating Uncertainty1
Volts ± (2.0 % + 3) 30 %
Earth Bond Resistance ± (1.5 % + 3) 30 %
Insulation Resistance Depends on test voltage and range. See Insulation Test specifications. 30 %

1This specification comes from the standard and indicates the maximum amount allowable by the standard.

EN61557 influence variables and uncertainties

Earth Bond Resistance Uncertainty for Uncertainty for
Influence Variable Designation per EN61557 Insulation Resistance Earth Bond Resistance
Supply Voltage E2 5 % 5 %
Temperature E3 5 % 5 %

1Specification confidence level 99 %.

The following tables can be used to determine the maximum or minimum display values considering maximum instrument operating error per EN61557-1, 5.2.4.

Insulation resistance maximum and minimum display values

50 V 100 V 250 V 500 V 1000 V
Minimum Minimum Minimum Minimum Minimum
Limit Value Display Limit Value Display Limit Value Display Limit Value Display Limit Value Display
Value Value Value Value Value
0.05 0.07 0.05 0.07 0.05 0.07 0.05 0.07
0.06 0.08 0.06 0.08 0.06 0.08 0.06 0.08
0.07 0.09 0.07 0.09 0.07 0.09 0.07 0.09
0.08 0.10 0.08 0.10 0.08 0.10 0.08 0.10
0.09 0.12 0.09 0.12 0.09 0.12 0.09 0.12
0.1 0.13 0.1 0.13 0.1 0.13 0.1 0.13 0.1 0.1
0.2 0.26 0.2 0.26 0.2 0.26 0.2 0.26 0.2 0.3
0.3 0.39 0.3 0.39 0.3 0.39 0.3 0.39 0.3 0.4
0.4 0.52 0.4 0.52 0.4 0.52 0.4 0.52 0.4 0.5
0.5 0.65 0.5 0.65 0.5 0.65 0.5 0.65 0.5 0.7
0.6 0.78 0.6 0.78 0.6 0.78 0.6 0.78 0.6 0.8
0.7 0.91 0.7 0.91 0.7 0.91 0.7 0.91 0.7 0.9
0.8 1.04 0.8 1.04 0.8 1.04 0.8 1.04 0.8 1.0
0.9 1.17 0.9 1.17 0.9 1.17 0.9 1.17 0.9 1.2
1.0 1.30 1.0 1.30 1.0 1.30 1.0 1.30 1.0 1.3
2.0 2.60 2.0 2.60 2.0 2.60 2.0 2.60 2.0 2.6
3.0 3.90 3.0 3.90 3.0 3.90 3.0 3.90 3.0 3.9
4.0 5.20 4.0 5.20 4.0 5.20 4.0 5.20 4.0 5.2
5.0 6.50 5.0 6.50 5.0 6.50 5.0 6.50 5.0 6.5
6.0 7.80 6.0 7.80 6.0 7.80 6.0 7.80 6.0 7.8
7.0 9.10 7.0 9.10 7.0 9.10 7.0 9.10 7.0 9.1
8.0 10.40 8.0 10.40 8.0 10.40 8.0 10.40 8.0 10.4
9.0 11.70 9.0 11.70 9.0 11.70 9.0 11.70 9.0 11.7
10.0 13.0 10.0 13.0 10.0 13.0 10.0 13.0 10.0 13.0
20.0 26.0 20.0 26.0 20.0 26.0 20.0 26.0 20.0 26.0
30.0 39.0 30.0 39.0 30.0 39.0 30.0 39.0 30.0 39.0
40.0 52.0 40.0 52.0 40.0 52.0 40.0 52.0 40.0 53.0
50.0 65.0 50.0 65.0 50.0 65.0 50.0 65.0
60.0 78.0 60.0 78.0 60.0 78.0 60.0 78.0
70.0 91.0 70.0 91.0 70.0 91.0 70.0 91.0
80.0 104.0 80.0 104.0 80.0 104.0 80.0 104.0
90.0 117.0 90.0 117.0 90.0 117.0 90.0 117.0
100.0 130.0 100.0 130.0 100.0 130.0
200.0 260.0 200.0 260.0
300.0 390.0 300.0 390.0
400.0 520.0 400.0 520.0
500.0 650.0
600.0 780.0
700.0 910.0
800.0 1040.0
900.0 1170.0
1000.0 1300.0
2000.0 2600.0

Earth bond resistance maximum display values

Limit Value Maximum Display Value
0.4 0.28
0.5 0.35
0.6 0.42
0.7 0.49
0.8 0.56
0.9 0.63
1.0 0.7
2.0 1.4
3.0 2.1
4.0 2.8
5.0 3.5
6.0 4.2
7.0 4.9
8.0 5.6
9.0 6.3
10.0 7.0
20.0 14.0
30.0 21.0
40.0 28.0
50.0 35.0
60.0 42.0
70.0 49.0
80.0 56.0
90.0 63.0
100.0 70.0
200.0 140.0
300.0 210.0
400.0 280.0
500.0 350.0
600.0 420.0
700.0 490.0
800.0 560.0
900.0 630.0
1000.0 700.0
2000.0 1400.0
 

Your basket is empty

Similar Products

Fluke 1577 Insulation Tester Meg Ohm Meter/Tester
RRP £405.00 YOUR PRICE £387.00+VAT We save you £18.00
Fluke 1503 Insulation Tester
YOUR PRICE £256.00
Additional Options

Best Sellers

Corgi -StopFrost Heating Cable System- STPF040
RRP £64.99 YOUR PRICE £53.99+VAT We save you £11.00
Quooker Pro3 Basic Polished Chrome 3 Litre Instant Boiling Water. 3BCHR
RRP £691.67 YOUR PRICE £529.99+VAT We save you £161.68

Featured Products

Dyson Airblade - AB03
RRP £599.00 YOUR PRICE £535.00+VAT We save you £64.00
Manrose XF100T 4 inch Wall Fan Timer
RRP £19.99 YOUR PRICE £12.49+VAT We save you £7.50