Advanced, multifunctional digital measuring instrument for low voltage electrical installation safety testing in accordance with IEC / EN 61557.

Best selling installation tester in Europe!
RRP £995.00 YOUR PRICE £619.99+VAT We save you £375.01
Add Items to Cart

Measuring Functions

BetaPAT is suitable for periodic testing, troubleshooting or as a tool for electrical safety testing in workshops.

  • DC insulation resistance measurement,
  • PE voltage drop / earth bond continuity test,
  • leakage current measurement and functional test.
  • Other features

  • 120 Pre-programmed Autotest sequences are stored in the instrument's memory and they cover most of the test procedures required by PAT standards. Autotest sequences give information on allowed standard-set  limits for all test parameters and essentially accelerate measuring procedure.
  • Possibility to create and store Custom Autotests sequences.
    Multifunction, alphanumeric keyboard allows specific data entries (appliance description, location, etc.).
  • Appliance identification and access to the test sequence via Barcode reader or RFID tags.
  • BetaPAT  MI2141 is suitable for applications where AC dielectric test is not required (e.g. periodic testing).
  • Optional: 110 V version.
  • Software

    PC software Pat Link with RS 232 cable

    Technical data

    Dimensions (w x h x l): 345 x 160 x 335 mm

    Mass (without accessories): 9 kg

       Insulation Resistance
    Display range 0 – 1000MOhms (Un=250 V) 0 – 200 MOhms (Un<250 V)
    Resolution 0.001 0.01 0.1 1 MOhms
    Accuracy ±(2 % + 2 Digits)…(0 – 200 MOhms)
    Test voltage 50 100 250 500 1000 V
    Generator current capability >1 mA

       Continuity of Protection Conductors (single measurement)
    Display range 0.00 – 19.99 20.0 – 199.9 200 - 2000 Ohms
    Accuracy ±(2 % + 2 Digits)….(0 – 20 O)
    Open-terminal test voltage 4 – 7 Vd.c.
    Test current >200 mA
    Compensation of test leads yes
    Automatic polarity exchange yes

       Continuity (continuous measurement)
    Display range 0.0 – 199.9 Ohms 200 – 2000 Ohms
    Accuracy ±(3 % + 3 Digits)
    Short-circuit test current <7 mA
    Open-terminal voltage 4 – 7 Vd.c.

       RCD Protection Devices – general data
    Nom. test current 10; 30; 100; 300; 500; 1000 mA (0 or 180 °C)
    RCD type AC, standard or selective

       RCD – Contact Voltage
    Display range 0.00 – 9.99 10.0 – 100 V
    Resolution 0.01 0.1 V
    Basic accuracy (-0 / +10)% ± 0.2 V (-0 / +10) %
    Test current <0.5 I?N

       RCD – Earth/Loop Resistance
    Measurement principle with or without probe
    Display range 0 – 10 kO

       RCD – Trip out Time
    Display range (general type) 0 – 300 ms (0.5 I?N, I?N)
    0 – 150 ms (2 I?N) 0 – 40 ms (5 I?N)
    Display range (selective type) 0 – 500 ms (0.5 I?N, I?N)
    0 – 200ms (2 I?N) 0 – 150 ms (5 I?N)
    Accuracy ±3 ms

       RCD – Tripping Current
    Display range I? (0.2 – 1.1) I?N
    Display range t?/I? 0 – 300 ms
    Display range Uci (Uc/I?) 0 – 100 V

       Fault Loop Impedance / Resistance and Ipsc
    Display range Z, R, X 0.00 – 19.99 20.0 – 199.9 200 – 2000 Ohms
    Accuracy Z, R, X …Eurotest ±(2 % + 3 Digits)
    Accuracy R…Instaltest ±(5 % + 5 Digits)
    Display range Ipsc 0.06 A – 24.4 kA
    Nominal voltage 100 – 264 V 45 – 65 Hz

       Line Impedance / Resistance and Ipsc
    Display range Z, R, X 0.00 – 19.99 20.0 – 199.9 200 – 2000 Ohms
    Accuracy Z, R, X …Eurotest ±(2 % + 3 Digits)
    Accuracy R…Instaltest ±(5 % + 5 Digits)
    Display range Ipsc 0.06 A – 42.4 kA
    Nominal voltage 100 – 440 V 45 – 65 Hz

       N-PE Loop / Earth Resistance and Ipsc
    Test method internal generator (Earth resistance)
    Display range R l-pe 0.00 – 19.99 20.0 – 199.9 200 – 2000 Ω
    Accuracy R l-pe ±(2 % + 3 Digits)
    Display range Ipsc 0.06 A – 24.4 kA

       Phase rotation
    Display of result 1.2.3 or 2.1.3

       Voltage              Frequency
    Display range 0 – 440V   45.0 – 65.0 Hz
    Accuracy ±(2 % + 2 D) ± 0.2 Hz
    Nominal frequency range 45 – 65 Hz

       Current (True RMS)
    Measurement principle current clamp
    Display range 0 – 200 Amps
    Resolution 0.1 1 mA 0.01 0.1 1A
    Basic accuracy ±(5 %)…(0.1 – 100 Amps)
    Nominal frequency 50/60 Hz

       Peak Current
    Display range 5 – 280 Amps
    Basic accuracy ±(5 %)

       Varistor Overvoltage Protection. Devices – Breakdown Voltage
    Measurement principle d.c. voltage ramp (500 V/s)
    Display range 50 – 1000 V
    Accuracy ±(5 % + 10 V)

       Power (one-phase)
    Display range 0 – 88 k W/VA/Var
    Resolution 0.1 1 0.01 k 0.1 k W/VA/Var
    Accuracy ±(7 % + 1 D)
    Nominal voltage, frequency 10 – 440 V, 50/60 Hz
    Display range cosϕ 0 – 1

       Energy
    Calculation W = Σ P × Δt
    Display range 0 – 2000 kWh
    Accuracy ±(7 % + 1 Digits)

       GENERAL CHARACTERISTICS:
    Power supply 6 V (4 × 1.5 V IEC LR14)
    Dimensions (w × h × d) 265 × 110 × 185 mm
    Weight: 2,1 kg.

    Technical Specification

    Sorry there are no further technical specifications available for this product. Please call us for more information.

     

    Your basket is empty

    Additional Options

    Best Sellers

    Corgi -StopFrost Heating Cable System- STPF040
    RRP £64.99 YOUR PRICE £53.99+VAT We save you £11.00
    Quooker Pro3 Basic Polished Chrome 3 Litre Instant Boiling Water. 3BCHR
    RRP £691.67 YOUR PRICE £529.99+VAT We save you £161.68

    Featured Products

    Dyson Airblade - AB03
    RRP £599.00 YOUR PRICE £535.00+VAT We save you £64.00
    Manrose XF100T 4 inch Wall Fan Timer
    RRP £19.99 YOUR PRICE £12.49+VAT We save you £7.50