MD9030 TRMS general purpose digital multimeter
Email to a FriendView Product Description
Add to Wishlist
The Metrel TRMS general purpuse digital multimeter. Precision equipment from products4testing.co.uk
The TRMS digital multimeter MD 9030 has been designed for use both in the laboratory and in the harsh industrial maintenance and repair sector.
Test functions
- TRMS DC and AC voltage up to 1000 V
- TRMS DC and AC current measurement up to 10 A
- Diode test
- Resistance measurement
- Continuity test
- Frequency measurement
- Capacitance measurement
- Temperature measurement
Technical data
Dimensions (w x h x l): 87 x 35,5 x 186 mm
Mass (without accessories): 396 g
Technical Specification
| Function | Range | Accuracy |
| DC voltage | 400.0 mV ÷ 1000 V | from ±(0.3 % of reading + 4 digits) to ±(1.0 % of reading + 4 digits) |
| TRMS AC voltage 50 Hz - 500 Hz | 400.0 mV ÷ 1000 V | from ±(1.5 % of reading + 5 digits) to ±(4.0 % of reading + 5 digits) |
| DC current measurement | 400.0 μA ÷ 10.0 A | from ±(1.2 % of reading + 3 digits) to ±(2.0 % of reading + 5 digits) |
| TRMS AC current measurement | 400.0 μA ÷ 10.0 A | from ±(1.5 % of reading + 4 digits) to ±(2.0 % of reading + 6 digits) |
| Diode test | Open-circuit voltage <1.6 V DC, Test current 0.25 mA | |
| Resistance measurement | 400.0 Ω ÷ 40.00 MΩ | from ±(0.6 % of reading + 4 digits) to ±(2.0 % of reading + 4 digits) |
| Temperature measurement | -20 °C ÷ 300 °C | ±(2 % + 3 ºC) |
| Frequency | 5 Hz ÷ 1000 Hz | ±(0.5 % of reading + 4 digits) |
| Capacitance | 500.0 nF ÷ 3000 μF | ±(3.5 % of reading + 6 digits) |
| Power supply | 2 x 1.5 V AAA size batteries | |
| Overvoltage category | CAT III/600 V, CAT II/1000 V | |
| Pollution degree | II | |